Skip to content
Dave Brown

Leading an engineering team

Structuring, leveling, measuring and motivating an engineering team as it grows, and rolling out AI coding tools without the chaos.

In depth

  1. How should I structure my engineering team at 5, 10 and 20 engineers?

    At 5 engineers, keep one team led by a senior tech lead. At 10, split into two teams of about 5, each owning a product area, with one engineering manager. At 20, run three or four teams of 5 to 6 with two or three managers and a clear head of engineering. Structure should follow the product, not the org chart.

    Read the full answer

  2. When should I hire my first engineering manager?

    Hire your first engineering manager when you have 8 to 10 engineers, or earlier if your best engineer spends most of the week on one-on-ones, hiring and unblocking instead of building. Below 6 engineers a strong tech lead is usually enough. Waiting past 12 reports per lead almost always costs you retention and delivery.

    Read the full answer

  3. How do I measure developer productivity?

    Measure the team's delivery, not individual output. Track four DORA metrics: deployment frequency, lead time for changes, change failure rate, and time to restore service. Pair them with one product outcome, like features adopted. Never rank developers by lines of code, commits or pull requests, because people will game those numbers within weeks.

    Read the full answer

  4. Why is my development team so slow?

    Most slow dev teams are slow because of the system around them, not their effort. The usual causes are shifting priorities, work batches that are too large, slow code reviews and deploys, accumulated tech debt, and too many things in progress at once. Diagnose by tracking where work waits, since waiting usually accounts for most of the delay.

    Read the full answer

  5. How do I build an engineering career ladder for a small company?

    Keep it small: 4 or 5 levels (junior, mid, senior, staff, and a lead or manager step), two tracks (individual contributor and management), a one-page description of expectations per level, and a pay band for each. Write it once, calibrate it against your actual team, and revisit it every 6 to 12 months.

    Read the full answer

  6. How do I keep engineers motivated and stop my best ones leaving?

    Keep engineers by giving them meaningful problems, a manager who notices them, autonomy over how they work, fair pay, and a visible path to grow. Pay alone rarely retains people, but underpaying will lose them. Talk to your best engineers every month about what would make them leave, rather than waiting for a resignation.

    Read the full answer

  7. How do I roll out AI coding tools like Cursor or Claude Code across my team?

    Start with a 2 to 4 week pilot of three or four willing engineers, set written rules for security and code review, pick one or two tools, share what works, then expand to the whole team over 6 to 8 weeks. Measure cycle time and defect rates, not lines generated. Budget roughly $20 to $200 per engineer per month.

    Read the full answer

  8. What should a CEO ask the CTO for to know engineering is on track?

    Ask your CTO for a monthly one-page report covering what shipped against plan, delivery metrics (deploy frequency, lead time, failure rate), top three risks, security and uptime status, cloud and headcount spend, and the plan for next quarter. Review it together monthly. Plain language and trends over time matter more than any single number.

    Read the full answer

Quick answers

Will hiring more engineers make us ship faster?

Usually not in the short term, because a new engineer tends to slow a team down for the first three to six months while they learn the codebase. Adding people helps when the work splits cleanly into independent pieces and raw capacity is the real bottleneck. If releases are slow because of unclear priorities, slow code review, or a fragile deploy process, new hires will just queue behind the same problems. Before you open a req, find where work waits for days and fix the biggest wait first.

Are DORA metrics worth tracking for a small startup?

Yes, but only the four core numbers and only as a conversation starter. DORA tracks deployment frequency, lead time for changes, change failure rate, and time to restore service. A team with fewer than 10 engineers can pull most of these from its Git history and incident log in an afternoon. Use them to spot trends over a quarter, not to rank individuals. Skip the dashboards until your deploy pipeline records every release, since a number built on guesses will mislead you. Review the four numbers with the team once a month.

Should a startup use Scrum and sprints, or something lighter?

For most startups under 15 engineers, use something lighter: a shared priority list, a weekly planning meeting, and a short daily written update. Full Scrum with sprint ceremonies, story points, and velocity charts costs time a small team rarely has, and the numbers mostly measure estimation habits. Keep sprints if you have outside customers who need predictable delivery dates or if your team already works well in them. Revisit the process when you pass about 15 engineers or when two teams start blocking each other every week.

Does a small team need an on-call rotation?

Yes, once customers pay for a production system, because someone has to own outages at night and on weekends. For a team of five to ten engineers, a weekly rotation with one primary and one backup is enough. Pay people for the on-call time, page only for real customer-facing problems, and fix the alerts that wake people up for things that do not matter. If nobody on the team can be paged safely, you have a staffing problem, not an on-call problem.

How do I handle an engineer who is underperforming?

Start with a private conversation that names the specific gap, such as missed deadlines, low-quality code, or slow reviews, and asks what is getting in the way. Many performance problems come from unclear expectations or a missing skill, so check those first. Write down the agreed expectations and a review date about 30 to 60 days out, and meet weekly in that window. If the gap closes, you have a stronger engineer. If it does not, you have a clear record that makes the next step fair to them and to the team. Involve HR early for anything that touches a protected category.

When is it time to let a developer go?

It is time when the same problem has been named clearly, given a written plan, and still has not improved by the end of that plan, usually 60 to 90 days. First check that expectations were clear and that the person had the tools and support to succeed. Separately, act without waiting for a plan if someone breaks trust through dishonesty, harassment, or repeated security violations, because a performance plan cannot fix those. Before any termination, talk to an employment lawyer or your HR provider, since rules on notice, severance, and documentation vary by state and country. Document each step as it happens.

What incentives actually work for engineers?

Clear scope, real autonomy over how work gets done, and pay near the market median for your city or remote band are the incentives that hold up best. Engineers often leave over poor management, unclear priorities, and work that goes nowhere, so fix those before you add bonuses. Review pay regularly to keep it near the market. Equity helps at seed and Series A, where people accept lower cash for upside, but it fades as the company grows and needs a cash component. Specific public recognition costs nothing and works well.

Should I promote an engineering manager from within or hire externally?

Promote from within when you already have a strong senior engineer who wants to manage and whose team trusts them. Hire externally when the role needs experience you do not have yet, such as running several teams or hiring at scale. Internal promotions keep context and morale high, but they can leave the old team without its best builder. Give the new manager a trial period of about three months with clear goals, and ask the team for feedback. If you hire from outside, give that manager real decision rights in the first month so they do not become a passenger.

How many engineers should report to one manager?

Plan for five to eight direct reports for most engineering managers, and move toward eight when the team is experienced and works on well-defined problems. Go lower, around four to six, when the team is new, the work is ambiguous, or the manager also writes production code. Fewer reports means more time for one-on-ones, hiring, and unblocking people, which is the work that decides whether a team holds up. Once a manager has more than about ten reports, add a layer of leads or split the team.

Should I make AI coding tools mandatory for my engineers?

Not yet, and probably not as a hard rule. Offer AI coding tools to the whole team, pick one or two, and track whether review time, bug rates, and cycle time actually improve over the next two months. Mandates tend to produce resentment and performative use, while a few engineers who prove the value will pull others along. Set clear rules for what code can be shared with the tool, and require every AI-written change to get the same review as human code. Revisit mandates once the data and the team's habits are clear.

Where I come in. If this is a decision in front of you right now, it’s the kind of thing I help with through Engineering Organization & Leadership. Often begins with a short diagnostic phase, followed by ongoing advising through implementation.

Get in touch

Available for a small number of conversations.

If something here is relevant to a decision you’re facing, I’d like to hear about it.